Predictive Index Assessment Exam Prep
Free practice questions

Free PI Practice Questions

10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.

Start the free practice test → ★★★★★4.9/5 from 2,400+ candidates · No signup

The PI exam has 50 questions and runs 12 minutes.

These 10 free PI questions are organized by exam domain, so you can see how each part of the Predictive Index Assessment blueprint is tested. Reveal the answer and explanation under each question.

Domain 1: Verbal Reasoning

Question 1

A vertical pipe installed to provide circulation of air to and from the drainage system, which receives no discharge from any fixture, is defined as a:

Show answer & explanation

Correct answer: B - Vent stack

Domain 2: Numerical Reasoning

Question 2

A contractor backfills a section of building sewer before the required inspection is performed. Under the administrative provisions of the code, the inspector is authorized to:

Show answer & explanation

Correct answer: A - Require the covered work to be exposed for inspection

More PI practice questions

Question 3

An inspector observes a water heater in an interior utility room. The temperature and pressure relief valve discharge pipe is full size, is not threaded at its end, drains by gravity, and terminates about 4 inches above the bottom of the water heater's drain pan. Under the UPC, this installation is:

Show answer & explanation

Correct answer: C - Not acceptable, because discharge into the pan is prohibited

Question 4

Fuel-burning water heaters are prohibited in a bedroom, or in a closet opening directly into a bedroom, EXCEPT where the appliance is:

Show answer & explanation

Correct answer: D - A direct-vent appliance drawing combustion air from outdoors

Question 5

A commercial lawn irrigation system injects liquid fertilizer downstream of the backflow protection, and electric solenoid valves hold the zone piping under pressure continuously. The MINIMUM acceptable backflow protection for this connection is a:

Show answer & explanation

Correct answer: D - Reduced pressure principle assembly (RP)

Question 6

An atmospheric vacuum breaker is installed on a hose bibb serving a janitor's sink. Which condition would make this device unacceptable?

Show answer & explanation

Correct answer: A - A shutoff valve is installed downstream of the device

Question 7

Water rises 46 feet from the water meter to the highest fixture outlet in a building. When sizing the water distribution system, the pressure loss attributable to this elevation is approximately:

Show answer & explanation

Correct answer: B - 19.9 psi

Question 8

Absent approval from the Authority Having Jurisdiction for a reduced grade, a 3-inch horizontal drain 32 feet in length installed at the minimum slope required by the UPC will have a total fall of:

Show answer & explanation

Correct answer: C - 8 inches

Question 9

Each cleanout shall be installed so that it opens:

Show answer & explanation

Correct answer: A - In the direction of flow, or at right angles to it

Question 10

An individual vent serving a 3-inch fixture drain shall have a diameter of not less than:

Show answer & explanation

Correct answer: B - 1-1/2 inches

The rest of the PI blueprint

The PI exam also covers these domains. Drill them in the full free practice test:

That's 10 of 1,030

The full bank has 1,020 more PI questions with explanations.

Continue in the free practice test →

View plans